Sensor with MODBUS interface (DLS-MODBUS)
Article number
DLS-modbus
Description
DLS-MODBUS
The Wireless Value DLS-Modbus can read out the data from an external Modbus sensor and transmit it via the Wireless Value Online Portal. Measurement results are sent wirelessly to the Base Station, where the data can be used for monitoring and analysis.
- Memory to store 10,000 measurements
- Adjustable measurement interval
- IP65 ABS enclosure
- Suitable for wall mounting
- Existing system can easily be expanded with additional sensors
- Replaceable battery
- Unique network ID to prevent interference with other wireless systems
Specifications
General
| Battery type | AA |
| External power supply | Optional |
| Colour | Matte black |
| Battery life | Over 6 years |
| Model | Wireless module with Modbus protocol |
| Type | External Modbus sensor can be connected |
| Power supply | 1 AA 3.6 V lithium battery or between 8 and 30 VDC |
Measurement range
| Operating limits | -20°C to +80°C |
| Signal range | 1,600 metres in clear line of sight |
Legislation and standards
| RED (Radio Equipment Directive) | yes |
| CE | yes |
| EN 300 220 | yes |
Technical specifications
| 16 bits | 0.1 |
| 32 bits | 0.001 |
| Battery voltage | 3.6 |
| IP rating | IP65 |
| External antenna | Optional |
| Memory | 10,000 measurements |
| Overpressure protection | Optional |
Dimensions
| Housing dimensions | 190 (l) x 100 (w) x 43 (h) |
| Weight | 270 grams |